SWITCH , PRESSURE

Definition:

A SWITCH WHICH IS ACTUATED BY CHANGES IN PRESSURE OF ANY GAS OR LIQUID OR BY CHANGES IN A VACUUM ACTING UPON ITS SENSING ELEMENT. EXCLUDES BAROSWITCH; SWITCH, PRESSURE-THERMOSTATIC; AND SWITCH, SENSITIVE.

CAGE Information

Code Company
56365 SCHNEIDER ELECTRIC USA INC. DBA SCHN

Federal Supply Class

Title

SWITCHES

Inclusions:

INCLUDES ROTARY, KNIFE, TOGGLE, PUSH BUTTON, MERCURY, THERMOSTATIC, AND DIFFERENTIAL PRESSURE SWITCHES.

Exclusions:

EXCLUDES SWITCHGEAR.

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
CTZB CONTACT VOLTAGE RATING IN VOLTS 120.0 AC AT SEA LEVEL SECOND VOLTAGE
CTYS CONTACT ADJUSTMENT TYPE INTERNAL ACTUATION POINT SCREW AND INTERNAL DEACTUATION POINT SCREW
FREQ FREQUENCY IN HERTZ 60.0 FIRST VOLTAGE
CTYM CONTACT ADJUSTMENT RANGE +550.00/+5000.00 ACTUATION POINT POUNDS PER SQUARE INCH AND +350.00/+4400.00 DEACTUATION POINT POUNDS PER SQUARE INCH
CTZL PRESSURE CONNECTOR TYPE PLAIN, THREADED INTERNAL SINGLE CONNECTION
CSCF TERMINAL TYPE SCREW
MEDA MEDIA FOR WHICH DESIGNED LIQUID
CTZB CONTACT VOLTAGE RATING IN VOLTS 600.0 DC AT SEA LEVEL THIRD VOLTAGE
CQJB PROOF PRESSURE 10000.00 POUNDS PER SQUARE INCH
CQGB CONTACT ACTION STIMULUS INCREASE
AXGY MOUNTING METHOD LINE
CTHF CONTACT LOAD CURRENT RATING 10.0 AMPERES INDUCTIVE LOAD SECOND VOLTAGE
STYL STYLE DESIGNATOR RECTANGULAR
CTHF CONTACT LOAD CURRENT RATING 10.0 AMPERES RESISTIVE LOAD THIRD VOLTAGE AND 10.0 AMPERES RESISTIVE LOAD FOURTH VOLTAGE AND 10.0 AMPERES RESISTIVE LOAD SECOND VOLTAGE AND 10.0 AMPERES RESISTIVE LOAD FIRST VOLTAGE AND 10.0 AMPERES INDUCTIVE LOAD FOURTH VOLTAGE
CTHF CONTACT LOAD CURRENT RATING 10.0 AMPERES INDUCTIVE LOAD FIRST VOLTAGE
ABMK OVERALL WIDTH 1.640 INCHES NOMINAL
CTZB CONTACT VOLTAGE RATING IN VOLTS 115.0 DC AT SEA LEVEL FOURTH VOLTAGE
CTYC CONTACT ADJUSTABILITY ACTUATION POINT ADJUSTABLE AND DEACTUATION POINT ADJUSTABLE
CTHF CONTACT LOAD CURRENT RATING 10.0 AMPERES INDUCTIVE LOAD THIRD VOLTAGE
ABKW OVERALL HEIGHT 6.970 INCHES NOMINAL
CTZB CONTACT VOLTAGE RATING IN VOLTS 600.0 AC AT SEA LEVEL FIRST VOLTAGE
ABHP OVERALL LENGTH 3.970 INCHES NOMINAL
CRLD NONPILE-UP CONTACT ARRANGEMENT 2 POLE, DOUBLE THROW, ONE POSITION MOMENTARY
FREQ FREQUENCY IN HERTZ 60.0 SECOND VOLTAGE
AJZC PRESSURE SWITCH TYPE DIFFERENTIAL
ADAU BODY HEIGHT 3.970 INCHES NOMINAL